What is a low-temperature water tank?
A cryostat is an essential piece of equipment for laboratory use. There are internal circulation and external circulation. The external circulation can be used to lead the constant temperature liquid out of the bath to establish a second constant temperature field, and it can also be used as a cold source (heat source) to lead the liquid out of the bath.
It is widely used in bioengineering, national defense, medicine, food, chemical industry, chemical analysis, petroleum and other fields, providing users with a constant field source with high precision, controllability and uniform temperature, and is an ideal choice for all small constant temperature water baths.
What are the advantages of NOKI's low-temperature water tank?
1. Adopt microcomputer temperature control PID adjustment high technology, high precision temperature control.
2. Intelligent full digital system can correct the temperature measurement value deviation, is the digital display resolution to 0.1 ℃. 4.
4. refrigeration system with multiple protection functions against overheating and overcurrent. 5.
5. Intelligent instrument control, simple operation, high-temperature stability, with upper and lower limits of the over-temperature alarm function.
6. Equipped with a full efficient anti-interference compressor.
7. Faster cooling speed than similar products, low noise, and vibration.
What are the parameters of the low-temperature water tank?
Model | Temperature range(℃) | Temperature fluctuation(℃) | Studio size(mm) | Groove depth(mm) | Pump flow(L/min) | Size of the opening(mm) |
---|---|---|---|---|---|---|
DC-0506 | -5~100 | ±0. 1 | 250x200x150 | 150 | 4 | 160×120 |
DC-0510 | 290×200×180 | 180 | 4 | 160×120 | ||
DC-0515 | 300×260×180 | 180 | 8 | 210×190 | ||
DC-0520 | 360×280×180 | 180 | 10 | 210×190 | ||
DC-0530 | 400×280×250 | 250 | 12 | 210×190 | ||
DC-1006 | -10~100 | ±0. 1 | 250x200x150 | 150 | 4 | 160×120 |
DC-1010 | 290×200×180 | 180 | 4 | 160×120 | ||
DC-1015 | 300×260×180 | 180 | 8 | 210×190 | ||
DC-1020 | 360×280×180 | 180 | 10 | 210×190 | ||
DC-1030 | 400×280×250 | 250 | 12 | 210×190 | ||
DC-2006 | -20~100 | ±0. 1 | 250x200x150 | 150 | 4 | 160×120 |
DC-2010 | 290×200×180 | 180 | 4 | 160×120 | ||
DC-2015 | 300×260×180 | 180 | 8 | 210×190 | ||
DC-2020 | 360×280×180 | 180 | 10 | 210×190 | ||
DC-2030 | 400×280×250 | 250 | 12 | 210×190 | ||
DC-3006 | -30~100 | ±0.1 | 250x200x150 | 150 | 4 | 160×120 |
DC-3010 | 290×200×180 | 180 | 4 | 160×120 | ||
DC-3015 | 300×260×180 | 180 | 8 | 210×190 | ||
DC-3020 | 360×280×180 | 180 | 10 | 210×190 | ||
DC-3030 | 400×280×250 | 250 | 12 | 160×120 | ||
DC-4006 | -40~100 | ±0.1 | 250x200x150 | 150 | 4 | 160×120 |
DC-4010 | 290×200×180 | 180 | 4 | 210×190 | ||
DC-4015 | 300×260×180 | 180 | 8 | 210×190 | ||
DC-4020 | 360×280×180 | 180 | 10 | 210×190 | ||
DC-4030 | 400×280×250 | 250 | 12 | 210×190 | ||
DCW-0506 | -6~100 | ±0. 1 | 200×160×180 | 180 | 4 | Φ70 |
DCW-1015 | -10~100 | 280×250×220 | 220 | 4 | Φ70 | |
DCW-2008 | -20~100 | 280×250×180 | 180 | 4 | Φ70 | |
DCW-3506 | -35~100 | ±0.1 | 250×200×180 | 180 | 4 | Φ70 |
DCW-3510 | 250×200×200 | 200 | 4 | Φ70 | ||
DCW-4006 | -40~100 | 250×200×180 | 180 | 8 | Φ70 |
Note:The above data were measured at ambient temperature (QT) 25℃ without load in the working room.